What was found
1) ON FINAL GREEN GEAR LITES EXTINGUISHED, RED GEAR LITE ILLUMINATED . ACCOMPLISHED ABNORMAL PROCEDURES . VIEWING PORT INDICATED N.G. DOWN & LOCKED. ON 2ND APPROACH , RED N.G. LITE EXTINGUISHED & GREEN N.G. LITE ILLUMINATED. ON GROUND WHEN TOW BAR WAS ATTACHED, RED NOSE GEAR LITE ILLUMINATED , GREEN LITE EXTINGUISHED . GEAR HORN SOUNDED. GEAR PINS REMOVED FROM POUCH & INSTALLED. 2) R&R NOSE GEAR DOWNLOCK SENSOR WITH SERVICEABLE SENSOR. OPS CHECK GOOD IAW MM 32-61-71, GEAR PINS REMOVED AND STOWED IAW BMM CH 32-00-11.