What was found
NR 2 ENG B-LOOP WON'T TEST. NR 2 ENG A-LOOP CHECKS GOOD. INSPECTED WIRING PER DC8 W/D 26-10-01, NO DEFECTS FOUND. REMOVED AND REPLACED NR 2 ENGINE FIRE DETECTOR UNIT IAW DACO MM 26-10-4. NR 2 FIRE WARNING TESTS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENG B-LOOP WON'T TEST. NR 2 ENG A-LOOP CHECKS GOOD. INSPECTED WIRING PER DC8 W/D 26-10-01, NO DEFECTS FOUND. REMOVED AND REPLACED NR 2 ENGINE FIRE DETECTOR UNIT IAW DACO MM 26-10-4. NR 2 FIRE WARNING TESTS GOOD.