What was found
FOUND 2 INCH CRACK LT FUSELAGE AT STA 1743 BETWEEN STR 16 & 17 ALSO FOUND A 1 INCH CRACK AT STA 1750 AT STR 15. PERFORMED MAJOR REPAIR PER TYPICAL REPAIR CALLED IN SRM 53-2-1, ITEM 16-B-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND 2 INCH CRACK LT FUSELAGE AT STA 1743 BETWEEN STR 16 & 17 ALSO FOUND A 1 INCH CRACK AT STA 1750 AT STR 15. PERFORMED MAJOR REPAIR PER TYPICAL REPAIR CALLED IN SRM 53-2-1, ITEM 16-B-2.