What was found
DURING C-CHECK, FOUND MAIN CARGO COMPARTMENT FLOOR PANEL CENTER TRACK FITTING CRACKED STA 200.000. REMOVED CRACKED FITTING PER SRM 51-1-20D PG 21. INSTALLED NEW FITTING PER SRM 51-1-20D PG 9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.