Service difficulty report · Control Panel · Airbus A300B4203

Difficulty date
February 11, 2003
Submitted
March 10, 2003
Operation
Air carrier
Aircraft
N362DH
Make and model
Airbus A300B4203
Aircraft serial
84
Part
Control Panel
Condition
Inoperative
Location
Smoke Detect
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON S/O'S PANEL, AND CARGO SMOKE DETECTION PANEL, THE AFT FAULT MAGNETIC INDICATOR IS AMBER. DUCT WON'T TEST. DEFERRED IAW MEL 26-11-01-2. PLACARD INSTALLED. CONTROL 11968. REF DMI 11968 ON S/O PANEL, THE ELEC CARGO SMOKE DETECTION PANEL. THE AFT DUCT FAULT M1 IS AMBER, IT WON'T TEST. RE-RACKED THE ELECTRIC AND CARGO SMOKE DETECTOR AMPLIFIER. SYSTEM OPS CHECKED GOOD IAW A300 26-14-04. THIS CLEARS DMI 11968. PLACARD REMOVED.