What was found
CORROSION ON AFT CARGO FORWARD DOOR FRAME, FRAME 59A WHERE FRAME MEETS SILL BEAM AT BOTTOM. REMOVED INTERCOSTAL AND GUSSETS TO GAIN ACCESS,CUT OUT DAMAGED LOWER FRAME SECTION IAW A NR SRM 53-17-00. TRIMMED ,LOCATED ABD DRILLED LOWER FRAME SECTION AND COUPLING IAW A300 SRM 53-17-00. INSTALLED LOWER FRAME SECTION COUPLING,INTERCOSTAL AND GUSSETS IAW A300 SRM 53-17-00 AT FRAMES 59A AFT CARGO.