What was found
LT WING INBOARD L/E FORMER WITH 0.500 INCH CRACK STA XFS 578.750. STOP DRILLED CRACK AT STA XFS 578.750 AND FABRICATED ANGLE DOUBLER (2024-T3 0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND ANGLE DOUBLER IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10, SRM 51-1-20D PG 9, 51-1-21 PG 1.