What was found
LT WING OUTBOARD L/E FORMER AT STA XFS 722.500 CRACKED 0.500 INCH. STOP DRILLED CRACK AND FABRICATED DOUBLER ANGLE (2024-T3 AL0.032) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND DOUBLER ANGLE IAW SRM 51-1-8B. INSTALLED DOUBLER ANGLE AT XFS 722.500 IAW SRM 57-2-0 PG 9-10, SRM 51-1-21 PG 1, SRM 51-1-20D PG 9.