As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT C/W AUX TANK - PERFORM ANTI-CORROSION TREATMENT TO LT 5056 ACCESS DOOR. REMOVED CORROSION ON LT 5056 ACCESS DOOR IAW SRM 51-1-8 PG. 17-18. FOUND OUT OF LIMITS IAW SRM 57-2-1 FIG.43. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED DOUBLER (7075-T6 AL0.080) IAW SRM 57-2-1 FIG.43. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER ON LT 5056 ACCESS DOOR IAW SRM 51-1-21 PG.1. SEE N/R 3824 FOR FUEL LEAK CK.