What was found
LT MLG W/W SPOILER AND AILERON ACTUATING MECH SUPPORT Z-FORMER CORRODED AT STA 857.000, LBL-54. REMOVED CORROSION ON FORMER IAW SRM 51-1-8 PG 17, 18. FOUND OUT LIMITS IAW SRM 53-2-0 PG 2P. REMOVED CORRODED Z-FORMER IAW SRM 51-1-21 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED FORMER IAW SRM 53-2-0 PG 1-2. CLEANED, TREATED AND PRIMED NEW FORMER IAW SRM 51-1-8B. INSTALLED NEW FORMER WITH NEW FASTENERS IAW SRM 51-1-21 PG 1, SRM 51-1-15 PG 1.