What was found
AFT LOWER CORNER OF AFT PASSENGER DOOR JAMB WITH 1.000 CRACK IN IT. PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 18 SHEET 1, TR 53-134, TR 53-135, DWG 5750776, DWG SR08530021. CUT OUT DAMAGED AREA AND FABRICATED FILLER (7075-T6 AL0.080) AND (2) DOUBLERS (7075-T6 AL0.090) (7075-T6 AL0.125) IAW SRM 53-2-0 FIG 18 SHEET 1, TR 53-134, TR 53-135, DWG 5750776, DWG SR08530021. CLEANED, TREATED AND PRIMED AREA AND FILLER AND DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FILLER AND DOUBLERS WITH NEW FASTENERS IAW SRM 53-2-0 FIG 18 SHEET 1, TR 53-134, TR 53-135, DWG 5750776, DWG SR08530021, SRM 51-1-20D PG 9, SRM 51-1-21 PG 1.