What was found
FWD ACCY COMPT FRAME CRACKED 2.000, STA 55.000, L-24L. TRIMMED OUT DAMAGED FRAME SEGMENT IAW SRM 53-2-0 FIG 2, TR 53-125, TR 53-110. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED NEW FRAME SEGMENT (7075-T6 AL0.071) AND SPLICE ANGLE (02 EA) (7075-T6 AL0.071) IAW SRM 53-2-0 FIG 2, TR 53-125, TR 53-110. PERFORMED HEAT TREATMENT TO FRAME SEGMENT AND NEW SPLICE ANGLES IAW SRM 51-1-1, DPS 7.00-1. CLEANED, TREATED AND PRIMED FRAME SEGMENT AND NEW SPLICE ANGLES IAW SRM 51-1-8B. INSTALLED FRAME SEGMENT AND NEW SPLICE ANGLES WITH NEW FASTENERS IAW SRM 53-2-0 FIG 2, TR 53-125, TR 53-110, SRM 51-1-20D PG 9, SRM 51-1-21 PG 1.