What was found
INTERIM REPAIR ON AFT LWR CORNER OF FWD SERVICE DOOR JAMB. PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 14, SHEET 2, TR 53-127, DWG 5750776, DWG SR08530021. REMOVED INTERIM REPAIR IAW SRM 51-1-21 PG 1. CUT OUT DAMAGED AREA AND FABRICATED FILLER AND 2 DOUBLERS IAW SRM 53-2-0 FIG 14, SHEET 2, TR 53-127, DWG 5750776, DWG SR08530021. CLEANED, TREATED AND PRIMED AREA AND FILLER AND DOUBLERS IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FILLER AND DOUBLERS WITH NEW FASTENERS IAW SRM 53-2-0 FIG 14, SHEET 2, TR 53-127, DWG 5750776, DWG SR08530021, SRM 51-1-20D PG 9, SRM 51-1-21 PG 1.