What was found
UPPER EXTERNAL FUSE SKIN CORRODED AT STA 1050.000 BETWEEN L-2R - L-2L. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 PG 2P. PERFORMED EDDY CURRENT INSPECTION IAW DC8 NDT SPM PART 06-10-01-001. CLEANED, TREATED AND PRIMED ARE IAW SRM 51-1-8B. FABRICATED FINGER DOUBLERS (02 EA) (7075-T6 AL0.050) AND DOUBLER (7075-T6 AL0.090) IAW EODHL-030553. CLEANED, TREATED AND PRIMED FINGER DOUBLERS AND DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FINGER DOUBLERS AND DOUBLER WITH NEW FASTENERS IAW EODHL-030553, ED-3307, SRM 51-1-20D PG 9, SRM 51-1-21 PG 1.