What was found
AFT ACCY COMPT END FITTING CRACKED 1.500, STA 1640.000 - STA 1660.000, L-30R. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1, SRM 53-4-1 FIG 43A SHEET 2. REMOVED CRACKED END FITTING IAW SRM 51-1-21 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED NEW END FITTING IAW SRM 53-1-0 PG 1, SRM 53-4-1 FIG 43A. PERFORMED HEAT TREATMENT TO NEW END FITTING IAW SRM 51-1-1, SRM 51-1-4, DPS 1.05-3, DPS 7.00-1. PERFORMED LIQUID PENETRANT INSPECTION IAW NDT SPM PART 08-00-02/06. CLEANED, TREATED AND PRIMED NEW END FITTING IAW SRM 51-1-8B. INSTALLED NEW END FITTING WITH NEW FASTENERS IAW SRM 51-1-21 PG 1.