What was found
FUSELAGE FRAME AT STA 520 IS DENTED BETWEEN STR 16-R AND 17-R. ROUTED CRACK AREA APPROX 730 X 1.210. FABRICATED REPAIR DOUBLER FROM 7075-T6 .063. TREATED AND PRIMED AND INSTALLED PER SRM 51-40-1 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.