What was found
1) APU FIRE DETECTION SYSTEM WILL NOT RESET AFTER FIRE TEST - INTERMITTENT.2) REPLACED APU FIRE DETECTION OPERATING POWER UNIT. FIRE DETECTION SYSTEM RESETS CONSISTENTLY. APU OPERATION NORMAL. M/M 26-15-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
1) APU FIRE DETECTION SYSTEM WILL NOT RESET AFTER FIRE TEST - INTERMITTENT.2) REPLACED APU FIRE DETECTION OPERATING POWER UNIT. FIRE DETECTION SYSTEM RESETS CONSISTENTLY. APU OPERATION NORMAL. M/M 26-15-00.