What was found
FUSELAGE FRAME AT STA 1090 BETWEEN STR 16R AND 17R HAS DENT AND ELONGATED HOLE. CUT OUT DAMAGED AREA PER SRM 51-40-3 FIG 1. FABRICATED REPAIR DOUBLER (7075-T6-.090) PER SRM 51-10-2. TREATED, PRIMED AND PAINTED AREA PER SRM 51-10-2. INSTALLED REPAIR PER SRM 51-40-3 FIG 1.