As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN BS 1166 AND 1148 STR 7.5 LT EACH HAVE GILLINER ATTACHING SUPPORT CHAFE MARKS INTO FRAME. CUT OUT DAMAGED AREA AT STA 1166 3 X 1 INCH, AND 1148 3 X 1 INCH PER SRM 51-40-3. FABRICATED DOUBLERS (7075-T6 .100) PER SRM 53-10-2 FIG 5. TREATED PARTS AND AREA, PRIMED PER SRM 51-10-2. INSTALLED 2 EA DOUBLERS PER SRM 51-10-2.