What was found
FUSELAGE FRAME AT STA 660 IS DENTED BETWEEN STR 16 R - 17 R. CUT OUT DAMAGED AREA, FABRICATED REPAIR PART (7075-T6 .063) PER SRM 51-40-3. CLEANED, TREATED AND PRIMED PER SRM 51-10-2. INSTALLED REPAIR PER SRM 51-40-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE FRAME AT STA 660 IS DENTED BETWEEN STR 16 R - 17 R. CUT OUT DAMAGED AREA, FABRICATED REPAIR PART (7075-T6 .063) PER SRM 51-40-3. CLEANED, TREATED AND PRIMED PER SRM 51-10-2. INSTALLED REPAIR PER SRM 51-40-1.