What was found
DURING (C) CHECK DISCREPANCY AS FOLLOWS, FUSELAGE SKIN HAS PILLOWING BETWEEN BS 294 AND 312 AT STR. 24 R. REMOVED RT FLOOR PANEL IN DOG HOUSE FOR ACCESS STA. 294 TO 330 RBL 30 IAW B-727 SRM 51-30-3. 2) CUT-OUT 2 EACH DAMAGE AREA 5 INCHES X 1.7500 INCH OF 8 INCHES X 1.7500 INCH IAW B-727 SRM 53-30-3 FIG. 3. 3) FABRICATED REPAIR DOUBLER 8 INCHES X 22 INCHES 2024-T3 .063 P.O. NR 9912380 IAW B-727 SRM 53-30-3 FIG. 3. 4) TREATED AND PRIMED IAW B-727 SRM 51-10-2. 5) INSTALLED REPAIR DOUBLER IAW B-727 SRM 53-30-3 FIG. 3. 6) INSTALLED ACCES PANEL IAW B-727 SRM 51-30-1.