What was found
DURING C-CHECK, FUSELAGE SKIN HAS 2 DENTS FWD AND AFT BS 1148 ABOVE STR 19L. BLENDED AREA (PREVIOUS) 2 EACH FOUND TO BE OUT OF LIMITS IAW B-727 SRM 53-30-1 FIG 1. CUT OUT DAMAGE AREA DIM 2.4 X 1.4 AND FAB REPAIR DOUBLER FROM MAT ID 2024-T3 .063 PO 9912380 DIM 11.5 X 8.75 AND FILLER FROM MAT ID 2024 T-3 .050 PO 9912380 DIM 2.4 X 1.4 IAW B-727 SRM 53-30-3 FIG 3. PARTS TREATED AND PRIMED IAW B-727 SRM 51-10-2. FAB AND INSTALLED REPAIR WASHERS IAW B-727 SRM 51-30-8 FIG 2. INSTALLED DOUBLER AND FILLER IAW B-727 SRM 53-30-3 FIG 1.