What was found
DURING C-CHECK DISCREPANCY AS FOLLOWS, IN AFT PIT BS 1050 FRAME HAS 3 EACH DENTS IN THE RADIUS BETWEEN STRINGERS 25L-27L. REMOVED FRAME SPLICES IAW B-727 SRM 51-30-2. CUT OUT DAMAGE AREA APPROX 3 INCHES IAW B-727 SRM 51-40-3. FABRICATED NEW SPLICE DOUBLER FOR FRAME BS 1050 BETWEEN STR 25L AND 27L MAT USED 7075-T6 .063 PO 9911326 DIMENSIONS 18.5 X 4 INCHES IAW B-727 SRM 51-40-3. ALODINED AND PRIMED IAW B-727 SRM 51-10-2. INSTALLED SPLICE DOUBLER AT BS 1050 BETWEEN STR 25L-27L IAW B-727 SRM 51-30-2 AND 51-40-3 FIG 1.