What was found
DURING C-CHECK, FUSELAGE SKIN TWO DENTS STA 430 BETWEEN STR 2R AND STR 3R. MEASURE DENT AND FOUND TO BE OUT OF LIMITS IAW B-727 SRM 53-30-1 FIG 1. REMOVED FASTENERS FOR ACCESS AND CUT OUT DAMAGE AREA DIM 4 INCH X 1.375 INCH AND FABRICATED ONE DOUBLER DIM 14 INCH X 9.5 INCH USING 2024 T-3 .050 PO 900226 IAW B-727 SRM 53-30-3 FIG 1. ALODINED AND PRIMED DOUBLER IAW B-727 SRM 51-10-2. INSTALLED DOUBLER REPAIR IAW B-727 SRM 51-30-2.