What was found
DURING C-CHECK, CABIN STRINGER 15 RT CRACKED STA 736D. REMOVED FASTENERS AS REQUIRED FOR ACCESS STRINGER 15R STA 736D IAW B-727 SRM 51-30-2. CUT OUT DAMAGED END OF STRINGER 15R DIM 7 INCHES AND FABRICATED ONE U-CHANNEL DIM 1 INCH X 1 INCH X 1 INCH X 4 INCH USING 7075 T6 .040 PO 900226 AND TWO EACH CHIMS 1 INCH X 1 INCH AND 1 INCH X 2.5 INCH USING 2024 T3 .080 PO 900103 IAW B-727 SRM 53-10-3 FIG 5. TREATED, ALODINED AND PRIMED ALL PARTS IAW B-727 SRM 51-10-2 AND INSTALLED REPAIRS IAW B-727 SRM 51-30-2.