What was found
DURING C-CHECK, N/R 60695 NR 7 SPOILER FITTING FWD ATTACHMENT ANGLES AT FALSE SPAR ARE CORRODED AND CRACKED WITH LOOSE AND PULLING FASTENERS. REMOVED FASTENERS FOR ACCESS IAW B-727 SRM 51-30-2 AND CUT OUT DAMAGED AREA AT NR 7 SPOILER FITTING FWD ATTACHMENT ANGLE DIMENSIONS 21 INCHES IAW B-727 SRM 51-40-3 FIG 1 AND 57-20-1 FIG 2. FABRICATED NEW ANGLE MAT USED BAC 1524-1432 PO 991286 AND ONE SPLICE DIM 12 INCHES SAME MATERIAL IAW B-727 SRM 51-40-3 FIG 1. ALODINED AND PRIMED REPAIR PARTS IAW B-727 SRM 51-10-2. INSTALLED NEW ANGLE AND SPLICE LEFT WING T/E FALSE SPAR IAW B-727 SRM 51-40-3.