As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK, AFT CARGO STA 1110 BLL O FLOOR SUPPORT BENT AND TWO SHEARED FASTENERS. REMOVED FASTENERS AS REQUIRED FOR ACCESS IAW B-727 SRM 51-30-2. CUT OUT DAMAGE AREA 2.25 X .875 INCH AND FABRICATED REPAIR ANGLE FROM BAC 1517-1360, EXTRUSION 10.5 X .75 X .75 INCH PO 318843 AND FILLER FROM 2.375 X .875 INCH PO 318843 IAW B-727 SRM 51-40-3 FIG 1. PARTS TREATED AND PRIMED IAW B-727 SRM 51-10-2. PARTS INSTALLED IAW B-727 SRM 51-40-3 FIG 1 AND 51-30-2.