What was found
DURING C-CHECK, RT ELEVATOR HAS TWO DINGS IN UPPER SKIN AT 30 INCHES FROM I/B EDGE, AND AT 30 INCHES O/B OF TAB CUTOUT. AT EACH DENT FOUND TO BE OUT OF LIMITS IAW B727 SRM 55-20-1 FIG 1. REMOVED 2 DAMAGED AREAS DIM .250 DIA AND FABBED REPAIR DOUBLERS FROM 2024-T3 .032 PO 9912070 DIM 6 X 3.5 INCH AND 4.5 X 3.875 INCH IAW B727 SRM 55-20-3 FIG 4. REPAIR PARTS TREATED AND PRIMED IAW B727 SRM 51-10-2 & INSTALLED IAW B727 SRM 55-20-3 FIG 4. CALCULATED ELEVATOR MOVEMENT TO BE 124.25 AND WITHIN THE .20_+_20 LIMITS IAE B727 SRM 51-80-7.