What was found
DURING D-CHECK, LOWER FUSELAGE EXTERIOR BS 277 TO 178 AREAS SKIN DEEP BLEND OUTS STR 25R TO 26R. STRIPPED PAINT IAW B-727 MM 51-20-01 AND FOUND LIGHTNING STRIKES DRILLED 6 EACH AREAS TO .250 AND INSTALLED FASTENERS IAW B-727 SRM 53-30-3 FIG 20. ONE EACH AREA FOUND TO BE OUT OF LIMITS IAW B-727 SRM 53-30-1 FIG 1. CUT OUT DAMAGED AREA AND FABBED REPAIR FILLER FROM 2024 T3 .040 PO 90024 DIM 3.75 X .75 INCH AND DOUBLER FROM 2024-T3 .050 PO 900414 DIM 10.25 X 8 INCHES IAW B-727 SRM 53-30-3 FIG 3. BARE METAL AND REPAIR PARTS TREATED AND PRIMED IAW B-727 SRM 51-10-2. INSTALLED IAW B-727 SRM 53-30-3 FIG 3.