As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON P6-3 CIRCUIT BREAKER PANEL NR 1 DETECTOR CIRCUIT GROUND LIGHT ILLUMINATED. TRANSFERRED NR 1 GROUND FAULT DETECTION SYSTEM TO DMI 11753 IAW MEL 26-9. PLACARD INSTALLED. RE; DMI 11753 - NR 1 GROUND FAULT ILLUMINATED. REPOSITIONED FIRE LOOP THAT WAS TOUCHING COWL, CHECKED GOOD PER 26-11-0. CLEARS DMI 11753. PLACARD REMOVED.