What was found
DURING "C" CHECK, N/R 53655, CABIN INTERIOR AT BS 560 DENT AND CRACK BTW. ST. 16R-17R. REMOVED FASTENERS FOR ACCESS IAW B-727 SRM 51-30-2. CUT OUT DAMAGED AREAS DIMENSIONS 1 X 1 INCH IAW B-727 SRM 51-40-3 FIG. 1. FABRICATED ANGLE REPAIR USING 7075-T6 .063 P.O. 9912475 DIMENSIONS 8 X 6 INCHES IAW B-727 SRM 51-40-3 FIG. 1. ALODINED AND PRIMED ALL REPAIR PARTS I.A.W. B-727 SRM 51-10-2. INSTALLED FRAME REPAIR IAW B-727 SRM 51-40-3 FIG. 1.