What was found
DURING C CHECK, PIT FLOOR SUPPORT FROM STA. (50 E TO STA. 990 LBL 14 HAS SEVERAL DENTS. REMOVED DAMAGED FLOOR SUPPORT FROM AFT. PIT STA. 950 E TO 990, LBL 14 I.A.W. B-727 SRM 51-30-2. DRILLED NEW FLOOR SUPPORT P.O. NR 328319, P/N BAC 1500-6199. 3) DIMENSION 5 INCHES, 10 INCHES IAW SAMPLE 51-20-1. 3) ALODINED AND PRIMED IAW B-727 SRM 51-10-2. 4) INSTALLED NEW FLOOR SUPPORT IAW B-727 SRM 51-30-2.