As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C CHECK, PIT FLOOR SUPPORT FROM STA. 950E TO STA. 990 RBL 14 HAS SEVERAL DENTS. CUT-OUT DAMAGED AREA AND FABBED FILLER FROM 7075 T6 .050 P.O. NR 9912793 DIM. 1.7500 INCH X 1INCH AND DOUBLER FROM 7075 T6 .063 P.O.NR 9912793 DIM. 6 INCHES X 2.500 INCHES IAW B-727 SRM 53-10-2 FIG. 8 AND 51-40-3 FIG. 1. PARTS TREATED AND PRIMED IAW B-727 SRM 51-10-2 AND INSTALLED IAW B-727 SRM 51-40-3 FIG. 1.