What was found
DISCREPANCY DURING (C) CHECK. FUSELAGE EXTERIOR LT. BS720E. TOP SEAM SHOW DENTED AREA OUT OF LIMITS. ST19L. C/A; REMOVED FAIRING 5338-3339, LT WING ANTI ICE DUCT STA 90.3-130, LT WING ROOT LE REMOVED DISC HYDRAULIC LINES WS 90.5 TO 130.7, DUCT AC LT FUS.. REMOVED FASTENERS AND MAKE CUT OUT DAMAGED AREA (3 INCHES). (6) PARTS MADE FROM 2024T3.063 PO NR 900355 DIM. (DOUBLER) 10.5 INCH X 10 INCH (FILLER) 3 INCH X 10 AND 7.5 INCH X 10.5 INCH(6). TREATED AND PRIMED PARTS AND AREA. INSTALLED PARTS REPAIR (6). INSTALLED LT WING ROOT LE ASSY, INSTALLED HYD LINES FROM 90.3 TO 130.7, PNEN. DUCTING (LT WING ANTI ICE) REMOVED AND REINSTALLED L/W. STA W. RING FROM LE STA 0 TO LE STA 171.