What was found
FWD SERVICE DOOR JAMB WITH 2.000 INCH CRACK IN AFT LWR CORNER STA 180.000 L-20R- L-21R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW DWG SR08530021, SRM 53-2-0 FIG 14. CUT OUT DAMAGED AREA IAW DWG DACCO SR08530021, SRM 53-2-0 FIG 14. FABRICATED FILLER, DOUBLER (7075-T6 0.063) AND TRIPLER (7075-T6 0.080) IAW DWG DACCO SR08530021, SRM 53-2-0 FIG 14. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. APPLIED (PRC) SEALANT TO FAYING SURFACES IAW SRM 51-1-15 PG 1. INSTALLED FILLER, DOUBLER AND TRIPLER WITH NEW FASTENERS IAW SRM 51-1-20D PG 9, DWG DACCO SR08530021, SRM 53-2-0 FIG 14, SRM 51-1-21 PG 1 AND SRM 51-1-21A PG 1-4.