What was found
LT WING OUTBOARD STUB WING FORMER CRACKED, STA XS 520.168. STOP DRILLED CRACK IAW SRM 57-2-0 PG 9-10. FABRICATED REINFORCING ANGLE (7075-T6 0.090) IAW SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED REINFORCING ANGLE IAW SRM 57-2-0 PG 9-10, SRM 51-1-21 PG 1 AND SRM 51-1-20D PG 9.