What was found
EXTERNAL FUSE CRACKED 1.000 INCH STA 1743.000 - STA 1746.000 BETWEEN L-16R AND L-17R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-1 FIG 7. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. CUT OUT DAMAGED AREA IAW SRM 53-2-1 FIG 7. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED FILLER (7075-T6 0.063), DOUBLER (7075-T6 0.071) AND FINGER DOUBLER (7075-T6 0.040) IAW SRM 53-2-1 FIG 7. CLEANED, TREATED AND PRIMED FILLER, DOUBLER AND FINGER DOUBLER IAW SRM 51-1-8B. INSTALLED CONICAL SPACER IAW SRM 51-1-26 FIG 1. INSTALLED FILLER, DOUBLER AND FINGER DOUBLER IAW SRM 53-2-1 FIG 7, SRM 51-1-15 PG 1 AND SRM 51-1-20D PG 9.