What was found
FUSE EXT - WEB LOWER PART CRACKED AT STA, 808.000 LBL 54.000. STOP DRILLED CRACK AT STA 808.000 LBL 54.000 IAW SRM 53-2-0, FABRICATED REINFORCEMENT (2024 T3 .040) IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED REINFORCEMENT ON FUS EXT WEB IAW SRM 53-2-0 FIG 1B, SRM 51-1-21 PG 1.