What was found
NOSE SECTION FUSELAGE - EXTERNAL SKIN CRACKED 0.750 AT STA 53.000, L-29L. PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 13. REMOVED DOUBLER AND FASTENERS IAW SRM 51-3-0 PG 1, SRM 51-1-20D PG 21. TRIMMED OUT CRACKED AREA IAW SRM 53-2-0 FIG 13 (SHEET 1). FABRICATED DOUBLER (2024-T3AL 0.071) AND FILLERS (2024-T3AL 0.050) IAW SRM 53-2-0 FIG 13 (SHEET 1, 5, 6). CLEANED, TREATED AND PRIMED FILLERS AND DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FILLERS AND DOUBLER WITH NEW FASTENERS IAW SRM 53-2-0 FIG 13 (SHEET 1, 5 ,6) SRM 51-1-20D PG 9.