What was found
EXTERNAL FUSELAGE INTERIM REPAIR STA 500.000 - STA 520.000, L21 - L24R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-1 FIG 7. REMOVED INTERIM REPAIR IAW SRM 51-1-21 PG 1. TRIMMED OUT DAMAGED AREA AND FABRICATED FINGER DOUBLER AND DOUBLER IAW SRM 53-2-1 FIG 7. CLEANED, TREATED AND PRIMED AREA, FINGER DOUBLER AND DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED FINGER DOUBLER AND DOUBLER WITH NEW FASTENERS IAW SRM 53-2-1 FIG 7 SRM 51-1-21 PG 1, SRM 51-1-20D PG 9.