What was found
LANDING GEAR DOOR UNLATCHED LIGHT WITH GEAR UP ON. COMPLETED ABNORMAL PROCEDURE LIGHT REMAINED ON. COMPLIED WITH RESTRICTIONS IN ABNORMAL PROCEDURE. MAY BE INOPERATIVE PER MEL 32-16-2 DMI 14484 PLACARD INSTALLED. REF. DMI 14484 LANDING GEAR DOOR UNLATCHED LIGHT WITH GEAR UP REMAINED ON. CHECKED TARGET STOPS, FOUND LEFT-HAND OUT OF ALIGNMENT. ADJUSTED IAW 32-60-0,OPS CHECKS NORMAL. THIS CLEARS DMI 14484 PLACARD REMOVED.