What was found
RT WING CENTER L/E FORMER CRACKED 0.250 AT XFS 316.000. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. STOP DRILLED CRACK IAW SRM 57-2-0 PG 9,10. FABRICATED REINFORCING ANGLE IAW SRM 57-2-0 PG 9,10. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INTALLED REINFORCING ANGLE WITH NEW FASTENERS IAW SRM 57-2-0 PG 9,10, SRM 51-1-21 PG 1.