What was found
INTERIM REPAIR ON FWD UPPER PLATING OF RT IB FLAP BETWEEN STA XW.104.000 AND XW.109.000. PERFORMED MAJOR REPAIR IAW SRM 57-1-0 PG 1, SRM 57-7-1 FIG 1. REMOVED FWD UPPER PLATING OF RT IB FLAP WITH INTERIM REPAIR IAW SRM 51-1-21 PG 1, SRM 51-3-0 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED NEW PLATING IAW SRM 57-7-1 FIG 1. CLEANED, TREATED AND PRIMED INNER FACE OF NEW PLATING IAW SRM 51-1-8B. INSTALLED NEW PLATING IAW SRM 51-1-21 PG 1, SRM 51-3-0 PG 1, SRM 51-1-15 PG 1.