What was found
RT OTBD. AILERON 0.750 DENTED ON UPPER PLATING AT ZA.651.000. PERFORMED MAJOR REPAIR IAW SRM 57-2-1 FIG 2X PG 30-31. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. TRIMMED OUT DAMAGED AREA IAW SRM 57-2-1 FIG 2X PG 30-31. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED REPAIR DOUBLER AND FAIRING PLATE IAW SRM 57-2-1 FIG 2X PG 30-31. CLEANED, TREATED AND PRIMED REPAIR DOUBLER INTERNAL PART AND FAIRING PLATE IAW SRM 51-1-8B. INSTALLED REPAIR DOUBLER AND FAIRING PLATE ON RT OTBD AILERON AT ZA.651.000 WITH NEW FASTENERS AND BONDED IAW SRM 57-2-1 FIG 2X PG 30-31, SRM 51-1-9 PARAGRAPH 3, SRM 51-1-21 PG 1.