What was found
NR 2 MAIN TANK SHOWS CLIP ATTACHING STRINGER 9 TO WING UPPER SKIN CRACKED (STA. 22.000, S-9L). REMOVED CRACKED CLIP IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW CLIP IN NR 2 MAIN TANK (LT WING), STA 22.000, S-9L IAW SRM 51-1-20D PG9. REFER TO NR 2088 FOR LEAK CHECK