What was found
AFT PASSENGER DOOR FWD LOWER JAMB CORNER SHOWS INTERIM REPAIR AT STA 1620.000, L-21L (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 18 PG 2-4. REMOVED FASTENERS AND INTERIM REPAIR. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. FABRICATED FILLER AND DOUBLER AND TRIPLER. CLEANED, TREATED AND PRIMED FILLER AND DOUBLER AND TRIPLER IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACE IAW SRM 51-1-11 PG 9. INSTALLED FILLER AND DOUBLER AND TRIPLER ON AFT PASSENGER DOOR FWD LOWER JAMB CORNER WITH NEW FASTENERS IAW SRM 53-2-0 FIG 18 PG 2-4, SRM 51-1-15 PG 1, SRM 51-1-21 PG 1, SRM 51-1-20D PG 9, SRM 51-3-0 PG 1.