What was found
RT OUTER WING TOP AFT PANEL PLATING CORRODED AROUND STA XRS 728.000 S-5 (MAJOR REPAIR). PERFORMED MAJOR REPAIR. REMOVED FASTENERS, REMOVED CORROSION, FOUND OUT OF LIMITS IAW SRM 57-2-0 PG.16. BLENDED OUT THE DAMAGED AREA, PERFORMED NDT INSPECTION AROUND REWORK AREA IAW DC8 NDT SPM PART 6-10-001. CLEANED, TREATED AND PRIMED. FABRICATED A REPAIR DOUBLER IAW EODHL-030621, ED-3470. CLEANED, TREATED AND PRIMED DOUBLER IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED DOUBLER ON RT OUTER WING TOP AFT PANEL PLATING (STA XRS.728.000, S-5) USING NEW FASTENERS IAW EODHL-030621, ED-3470, SRM 51-1-21 PG 1, SRM 51-1-20D PG 9. SEE N/R 2088 FOR LEAK CK.