What was found
ON APPROACH, FLAPS DID NOT EXTEND WITH FL 8 SELECTED. PERFORMED ABNORMAL PROCEDURE LANDED SL16/FL 0. ON TOUCHDOWN, FLAPS EXTENDED TO 8 DEGREES. CHECKED SERVICING ON THE FLAP CONTROL UNIT, DUPLEX AND SIMPLEX BEVEL GEARBOXES, TORQUE LIMITERS, DOWN DRIVE GEARBOXES, AND FLAP TEE GEARBOXES AS PER M/M 12-13-27. ALL GEARBOXES SERVICED NORMALLY. OPERATED FLAPS PER M/M 27-50-00. FLAPS OPERATE NORMALLY.