What was found
DURING C-CHECK, MAIN DECK COURIER AREA HAVE CORROSION EVIDENCE ON FLOOR PANEL SUPPORT/SEAT TRACK FROM APPROX FR 14 TO FR 15 RBL 0 TO RBL 20 (MARKED). REMOVED CORROSION FROM FR 14 TO FR 15 RBL 29, MAT LOSS .030, FOUND TO BE OUT OF LIMITS IAW A-300 SRM 53-10-00 FIG 612. REMOVED SEAT TRACK FROM FR 14 TO FR 19 RBL 20 IAW A-300 SRM 51-30-30. MATERIAL; USED P/N 60-22457 PO 23236312 TREATED, PRIMED AND POLYWHITE TRACK SECTION AS PER A-300 SRM 51-40-12. INSTALLED NEW SECTION OF SEAT TRACK IAW A-300 SRM 51-30-30 PAGE 8.