What was found
DURING C-CHECK, MAIN DECK COURIER AREA HAS CORROSION EVIDENCE ON FLOOR PANEL SUPPORT/SEAT TRACK FROM APPROX FR 14 TO FR 19 LBL 36 (MARKED). REMOVED CORROSION FROM FLOOR PANEL SUPPORT (SEAT TRACK) BETWEEN FR 14 TO FR 19, LBL 36 IAW A-300 SRM 51-40-11. MAT LOSS APPROXIMATELY 0.030, FOUND TO BE OUT OF LIMITS IAW A-300 SRM 53-10-00 FIG 612 (NOMINAL THICKNESS 0.090). REMOVED DAMAGED SEAT TRACK SECTION FROM FRAME 14 TO FRAME 19 LBL 36, IAW A-300 SRM 51-30-30. TRIM NEW SEAT TRACK EXTRUSION TO FIT, MATERIAL USED P/N 60-22457, PO 23236312 IAW A-300 SRM 51-27-00 AND 51-30-40. TREATED AND PRIMED AND POLIWHITE SEAT TRACK IAW A-300 SRM 51-40-12. INSTALLED NEW SEAT TRACK SECTION IAW A-300 SRM 51-30-30 AND 51-10-40.